Reason: The file is too large resulting in high CPU usage
Solution: It is recommended to use Eryone's default parameters for printing.
Reason:
1.Damage to the heating wire leads to
2.There is no silicone sleeve, resulting in a large deviation of the nozzle temperature within a short period of time leading to an error report
3.Broken heating pad
Solution:
1.Take a new one
2.Install a silicone sleeve
3.Change a new heating pad
Reason:
1.4-point leveling Z-axis distance calibration deviation is large, resulting in canceled printing
2.The nozzle does not detect the heatbed
Solution:
1.Check and adjust the belt tension.
2.Click “Home all”.
Cause: Problem with pressure sensor
Solution: Restart the printer and perform a Z-axis tilt calibration test
Reason: Poor contact on MCU motherboard
Solution: Turn off the computer and wait for a while before rebooting.
Cause: System files are missing
Solution: Reflash the firmware
For details:Firmwareinstallation